Address

Datapoint Typ

COIL/REG

R/W

Range

Unit

Name

WPM-Software J/L/M

WPM-Software H

Min

Max

Parallelverschiebung

5036

5002

uint16

Register

R/W

0

38

0: -19
1: -18
2: -17
3: -16
4: -15
5: -14
6: -13
7: -12
8: -11
9: -10
10: -9
11: -8
12: -7
13: -6
14: -5
15: -4
16: -3
17: -2
18: -1
19: 0

20: 1
21: 2
22: 3
23: 4
24: 5
25: 6
26: 7
27: 8
28: 9
29: 10
30: 11
31: 12
32: 13
33: 14
34: 15
35: 16
36: 17
37: 18
38: 19
 

Raumtemperatur

46

21

uint16

Register

R/W

15.0

30.0

°C

Festwertsolltemperatur

5037

5003

uint16

Register

R/W

18

60

°C

Heizkurvenendpunkt

5038

5015

uint16

Register

R/W

20

70

°C

Hysterese

47

22

uint16

Register

R/W

0.5

5.0

K

Solltemp. dyn. Kühlung (bis L22.9)

5043

5024

uint16

Register

R/W

10

35

°C

Solltemp. dyn. Kühlung bei 15°C AT (ab L22.9)

5043

-

uint16

Register

R/W

10

35

°C

Solltemp. dyn. Kühlung bei 35°C AT (ab L22.9)

5134

-

uint16

Register

R/W

10

35

°C