Betriebsdaten
Address | Datapoint Typ | R/W |
---|
8.4.4 Sensorik
...
Value
...
Description
...
1
...
Außenfühler (R1)
...
2
...
Rücklauffühler (R2)
...
3
...
Warmwasserfühler (R3)
...
4
...
Codierung (R7)
...
5
...
Vorlauffühler (R9)
...
6
...
2.Heizkreisfühler (R5)
...
7
...
3.Heizkreisfühler (R13)
...
8
...
Regenerativfühler (R13)
...
9
...
Raumfühler 1
...
10
...
Raumfühler 2
...
11
...
Fühler Wärmequellenaustritt (R6)
...
12
...
Fühler Wärmequelleneintritt (R24)*
...
14
...
Kollektorfühler (R23)
...
15
...
Niederdrucksensor (R25)
...
16
...
Hochdrucksensor (R26)
...
17
...
Raumfeuchte 1
...
18
...
Raumfeuchte 2
...
19
...
Fühler Frostschutz-Kälte
...
20
...
Heißgas
...
21
...
Rücklauffühler (R2.1)
...
22
...
Schwimmbadfühler (R20)
...
23
...
Vorlauffühler Kühlen Passiv (R11)
...
24
...
Rücklauffühler Kühlen Passiv (R4)
...
26
...
Fühler Solarspeicher (R22)
...
28
...
Anforderungsfühler Heizen (R2.2)
...
29
...
RTM Econ
...
30
...
Anforderungsfühler Kühlen (R39)
Info |
---|
*HINWEIS |
8.5 Eingänge
...
Address
...
Datapoint Typ
...
R/W
...
Bezeichnung
...
Smart-Grid 1
...
3d
...
boolean
...
R
...
Smart-Grid 2
...
4d
...
boolean
...
R
...
EVU-Sperre
...
1402d
...
boolean
...
R
...
Sperre Extern
...
1245d
...
boolean
...
R
Info |
---|
HINWEIS |
8.6 Ausgänge
...
Address
...
Datapoint Typ
...
R/W
...
Name
...
WPM-Software J/L
...
Verdichter 1
...
1500d
...
Boolean
...
R
...
Verdichter 2
...
1501d
...
Boolean
...
R
...
Ventilator (M2)
...
1502d
...
Boolean
...
R
...
Primärpumpe (M11)
...
1506d
...
Boolean
...
R
...
2.Wärmeerzeuger (E10)
...
1507d
...
Boolean
...
R
...
Heizungspumpe (M13)
...
1512d
...
Boolean
...
R
...
Warmwasserpumpe (M18)
...
1517d
...
Boolean
...
R
...
Mischer 1.Kreis Auf
...
698d
...
Boolean
...
R
...
Mischer 1.Kreis ZU
...
699d
...
Boolean
...
R
...
Mischer 2.Kreis Auf
...
1532d
...
Boolean
...
R
...
Mischer 2.Kreis ZU
...
1533d
...
Boolean
...
R
...
Mischer 3.Kreis Auf
...
1534d
...
Boolean
...
R
...
Mischer 3.Kreis ZU
...
1535d
...
Boolean
...
R
...
Mischer Bivalent Auf
...
1528d
...
Boolean
...
R
...
Mischer Bivalent ZU
...
1529d
...
Boolean
...
R
...
Mischer Regenerativ Auf
...
1530d
...
Boolean
...
R
...
Mischer Regenerativ ZU
...
1531d
...
Boolean
...
R
...
Zusatzumwälzpumpe (M16)
...
1516d
...
Boolean
...
R
...
Flanschheizung (E9)
...
1510d
...
Boolean
...
R
...
Heizungspumpe (M15)
...
1514d
...
Boolean
...
R
...
Schwimmbadpumpe (M19)
...
1518d
...
Boolean
...
R
...
Sammelstörmeldung (H5)
...
1523d
...
Boolean
...
R
...
Kühlpumpe (M17)
...
1519d
...
Boolean
...
R
...
Heizungspumpe (M20)
...
1515d
...
Boolean
...
R
...
Umschaltung Raumthermostate Heizen/Kühlen (N9)
...
1527d
...
Boolean
...
R
...
Primärpumpe Kühlen (M12)
...
1522d
...
Boolean
...
R
...
Solarpumpe (M23)
...
1454d
...
Boolean
...
R
Info |
---|
HINWEIS |
8.7 Zeitabgleich
Über den Zeitabgleich ist es möglich das aktuelle Datum und die Uhrzeit über die Schnittstelle zu schreiben. Damit die Änderung vom Wärmepumpenmanager übernommen wird, muss nach dem Schreiben der Zeit sofort noch der Wert 1 auf das zugehörige "set Register" geschrieben werden. Erst dann wird die Änderung übernommen. Der Wert des "set Registers" setzt sich nach dem Schreiben automatisch wieder auf den Wert 0 zurück.
Address
Datapoint Typ
R/W
Range
Unit
Name
Min.
Max.
Stunde
702u
uint16
R/W
0
23
hour
set Stunde
701d
boolean
W
Minute
703u
uint16
R/W
0
59
min
set Minute
702d
boolean
W
Monat
704u
uint16
R/W
1
12
month
set Monat
704d
boolean
W
Wochentag
705u
uint16
R/W
1
7
1:Montag
2: Dienstag
3: Mittwoch
4: Donnerstag
5: Freitag
6: Samstag
7: Sonntag
set Wochentag
706d
boolean
W
Tag
706u
uint16
R/W
1
31
day
set Tag
703d
boolean
W
Jahr
707u
uint16
R/W
0
99
year
set Jahr
705d
boolean
Range | |
---|---|
Name |
Außentemperatur (R1)
1301a
int16
R
°C
Temperatur Ruecklauf (R2)
1294a
int16
R
°C
Temperatur Rücklaufsoll
1620a
int16
R
°C
Temperatur Warmwasser (R3)
1305a
int16
R
°C
Temperatur Warmwassersoll
1594a
int16
R
°C
Temperatur Vorlauf (R9)
1300a
int16
R
°C
Temperatur Wärmequelleneintritt (R24)*
1303a
int16
R
°C
Temperatur Wärmequellenaustritt (R6)
1302a
int16
R
°C
Solltemperatur 2.Heizkreis
1622a
int16
R
°C
Temperatur 2.Heizkreis (R5)
1285a
int16
R
°C
Solltemperatur 3.Heizkreis
1624a
int16
R
°C
Temperatur 3.Heizkreis (R13)
1286a
int16
R
°C
Raumtemperatur 1 / RT-RTH Econ
1289a
int16
R
°C
Raumtemperatur 2
1291a
int16
R
°C
Raumfeuchte 1 / RT-RTH Econ
1288a
int16
R
°C
Raumfeuchte 2
1290a
int16
R
°C
Passiv Kühlen
Vorlauftemperatur (R11)
1299a
int16
R
°C
Rücklauftemperatur (R4)
1298a
int16
R
°C
Passiv/Aktiv Kühlen
Rücklauftemp. gem. Primärkreis (R24)
1296a
int16
R
°C
Solar
Kollektorfühler (R23)
1287a
int16
R
°C
Solarspeicher (R22)
1295a
int16
R
°C
Lüftung
Außenlufttemperatur
629a
int16
R
°C
Zulufttemperatur
630a
int16
R
°C
Ablufttemperatur
631a
int16
R
°C
Fortlufttemperatur
632a
int16
R
°C
Drehzahl Zuluftventilator
1559u
uint16
R
1/min
Drehzahl Abluftventilator
1560u
uint16
R
1/min
Info |
---|
*HINWEIS |
8.2 Historie
...
Address
...
Datapoint Typ
...
R/W
...
Unit
...
Name
...
Verdichter 1
...
1380u
...
uint16
...
R
...
hour
...
Verdichter 2
...
1381u
...
uint16
...
R
...
hour
...
Primärpumpe / Ventilator (M11)
...
1384u
...
uint16
...
R
...
hour
...
2.Wärmeerzeuger (E10)
...
1382u
...
uint16
...
R
...
hour
...
Heizungspumpe (M13)
...
1385u
...
uint16
...
R
...
hour
...
Warmwasserpumpe (M18)
...
1386u
...
uint16
...
R
...
hour
...
Flanschheizung (E9)
...
1387u
...
uint16
...
R
...
hour
...
Schwimmbadpumpe (M19)
...
1388u
...
uint16
...
R
...
hour
...
Zusatzumwälzpumpe (M16) (ab L12)
...
1390u
...
uint16
...
R
...
hour
...
Wärmemenge* Heizen 1-4
...
1300u
...
uint16
...
R
...
kWh
...
Wärmemenge* Heizen 5-8
...
1301u
...
uint16
...
R
...
kWh
...
Wärmemenge* Heizen 9-12
...
1302u
...
uint16
...
R
...
kWh
...
Wärmemenge* Warmwasser 1-4
...
1303u
...
uint16
...
R
...
kWh
...
Wärmemenge* Warmwasser 5-8
...
1304u
...
uint16
...
R
...
kWh
...
Wärmemenge* Warmwasser 9-12
...
1305u
...
uint16
...
R
...
kWh
...
Wärmemenge* Schwimmbad 1-4
...
1306u
...
uint16
...
R
...
kWh
...
Wärmemenge* Schwimmbad 5-8
...
1307u
...
uint16
...
R
...
kWh
...
Wärmemenge* Schwimmbad 9-12
...
1308u
...
uint16
...
R
...
kWh
Info |
---|
*HINWEIS |
8.2.1 Beispiel Wärmemengen*
Die Wärmemengen setzen sich aus 3 Indizes zusammen. Diese 3 Indizes müssen mit folgender Formel zur Wärmemenge zusammengesetzt werden.
Code Block | ||
---|---|---|
| ||
Wärmemenge Heizen = (Wärmemenge Heizen 9-12 * 100000000) + (Wärmemenge Heizen 5-8 * 10000) + Wärmemenge Heizen 1-4 |
Entsprechend dieser Beschreibung wird die Wärmemenge für "Warmwasser" und "Schwimmbad" ermittelt. Jedoch wird hierbei der entsprechende Datenpunkt genutzt.
8.3 Einstellungen
8.3.1 .Heizkreis
...
Address
...
Datapoint Typ
...
R/W
...
Range
...
Unit
...
Name
...
Min
...
Max
...
Parallelverschiebung
...
767u
...
uint16
...
R/W
...
0
...
38
...
0: -19
1: -18
2: -17
3: -16
4: -15
5: -14
6: -13
7: -12
8: -11
9: -10
10: -9
11: -8
12: -7
13: -6
14: -5
15: -4
16: -3
17: -2
18: -1
19: 0
...
20: 1
21: 2
22: 3
23: 4
24: 5
25: 6
26: 7
27: 8
28: 9
29: 10
30: 11
31: 12
32: 13
33: 14
34: 15
35: 16
36: 17
37: 18
38: 19
...
Raumtemperatur
...
700a
...
int16
...
R/W
...
15.0
...
30.0
...
°C
...
Festwertsolltemperatur
...
768u
...
uint16
...
R/W
...
18
...
60
...
°C
...
Heizkurvenendpunkt
...
766u
...
uint16
...
R/W
...
20
...
70
...
°C
...
Hysterese
...
701a
...
uint16
...
R/W
...
0.5
...
5.0
...
K
...
Solltemp. dyn. Kühlung bei 15°C AT
...
773u
...
uint16
...
R/W
...
10
...
35
...
°C
...
Solltemp. dyn. Kühlung bei 35°C AT
...
509u
...
uint16
...
R/W
...
10
...
35
...
°C
8.3.2 .Heizkreis
...
Address
...
Datapoint Typ
...
R/W
...
Range
...
Unit
...
Name
...
Min.
...
Max.
...
Heizkurvenendpunkt
...
851u
...
uint16
...
R/W
...
20
...
70
...
°C
...
Festwertemperatur
...
853u
...
uint16
...
R/W
...
20
...
60
...
°C
...
Parallelverschiebung
...
852u
...
uint16
...
R/W
...
0
...
38
...
0: -19
1: -18
2: -17
3: -16
4: -15
5: -14
6: -13
7: -12
8: -11
9: -10
10: -9
11: -8
12: -7
13: -6
14: -5
15: -4
16: -3
17: -2
18: -1
19: 0
...
20: 1
21: 2
22: 3
23: 4
24: 5
25: 6
26: 7
27: 8
28: 9
29: 10
30: 11
31: 12
32: 13
33: 14
34: 15
35: 16
36: 17
37: 18
38: 19
8.3.3 .3 .Heizkreis
...
Address
...
Datapoint Typ
...
R/W
...
Range
...
Unit
...
Name
...
Min.
...
Max.
...
Heizkurvenendpunkt
...
931u
...
uint16
...
R/W
...
20
...
70
...
°C
...
Festwertemperatur
...
933u
...
uint16
...
R/W
...
20
...
60
...
°C
...
Parallelverschiebung
...
932u
...
uint16t
...
R/W
...
0
...
38
...
0: -19
1: -18
2: -17
3: -16
4: -15
5: -14
6: -13
7: -12
8: -11
9: -10
10: -9
11: -8
12: -7
13: -6
14: -5
15: -4
16: -3
17: -2
18: -1
19: 0
...
20: 1
21: 2
22: 3
23: 4
24: 5
25: 6
26: 7
27: 8
28: 9
29: 10
30: 11
31: 12
32: 13
33: 14
34: 15
35: 16
36: 17
37: 18
38: 19
8.3.4 Modus
...
Address
...
Datapoint Typ
...
R/W
...
Range
...
Unit
...
Name
...
Min
...
Max
...
Betriebsmodus
...
714u
...
uint16
...
R/W
...
0
...
5
...
0: Sommer
1: Auto
2: Urlaub
3: Party
4: 2.Wärmeerzeuger
5: Kühlen
...
Anzahl Partystunden
...
715u
...
uint16
...
R/W
...
0
...
72
...
hour
...
Anzahl Urlaubstage
...
1108u
...
uint16
...
R/W
...
0
...
150
...
day
...
Lüftung
...
Stufen
...
1564u
...
uint16
...
R/W
...
0
...
5
...
Zeitwert Stoßlüften
...
1565u
...
uint16
...
R/W
...
15
...
90
Info |
---|
HINWEIS |
8.3.5 Warmwasser
...
Address
...
Datapoint Typ
...
R/W
...
Range
...
Unit
...
Name
...
Min
...
Max
...
Hysterese
...
1043u
...
uint16
...
R/W
...
2
...
15
...
K
...
Solltemperatur
...
1042u
...
uint16
...
R/W
...
Solltemp. Min.
...
85
...
°C
...
Solltemperatur Minimal
...
1045u
...
uint16
...
R/W
...
10
...
Soll.
...
°C
...
Solltemperatur Maximal
...
1044u
...
uint16
...
R/W
...
Soll.
...
85
...
°C
8.3.6 Schwimmbad
...
Address
...
Datapoint Typ
...
R/W
...
Range
...
Unit
...
Name
...
Min
...
Max
...
Hysterese
...
1150u
...
uint16
...
R/W
...
1
...
20
...
K
...
Solltemperatur
...
1153u
...
uint16
...
R/W
...
5
...
60
...
°C
...
Solltemperatur Minimal
...
1481u
...
uint16
...
R/W
...
10
...
60
...
°C
...
Solltemperatur Maximal
...
1155u
...
uint16
...
R/W
...
10
...
60
...
°C
8.3.7 .Wärmeerzeuger
...
Address
...
Datapoint Typ
...
R/W
...
Range
...
Unit
...
Name
...
Min
...
Max
...
Mischer Hysterese
...
564a
...
uint16
...
R/W
...
0.5
...
2.0
...
K
...
Grenztemperatur parallel
...
750u
...
uint16
...
R/W
...
-25
...
35
...
°C
...
Grenztemperatur alternativ
...
751u
...
uint16
...
R/W
...
30
...
85
...
Min
8.3.8 Warmwasser Sperre
...
Address
...
Datapoint Typ
...
R/W
...
Range
...
Unit
...
Name
...
Min
...
Max
...
Zeitfunktion
...
Start Stunde 1
...
1050u
...
uint16
...
R/W
...
0
...
23
...
hour
...
Start Minute 1
...
1051u
...
uint16
...
R/W
...
0
...
59
...
min
...
Ende Stunde 1
...
1052u
...
uint16
...
R/W
...
0
...
23
...
hour
...
Ende Minute 1
...
1053u
...
uint16
...
R/W
...
0
...
59
...
min
...
Start Stunde 2
...
1054u
...
uint16
...
R/W
...
0
...
23
...
hour
...
Start Minute 2
...
1055u
...
uint16
...
R/W
...
0
...
59
...
min
...
Ende Stunde 2
...
1056u
...
uint16
...
R/W
...
0
...
23
...
hour
...
Ende Minute 2
...
1057u
...
uint16
...
R/W
...
0
...
59
...
min
...
Sonntag
...
1064u
...
uint16
...
R/W
...
0
...
3
...
Montag
...
1058u
...
uint16
...
R/W
...
0
...
3
...
Dienstag
...
1059u
...
uint16
...
R/W
...
0
...
3
...
Mittwoch
...
1060u
...
uint16
...
R/W
...
0
...
3
...
Donnerstag
...
1061u
...
uint16
...
R/W
...
0
...
3
...
Freitag
...
1062u
...
uint16
...
R/W
...
0
...
3
...
Samstag
...
1063u
...
uint16
...
R/W
...
0
...
3
...
0: Ja
1: Nein
2: Zeit 1
3: Zeit 2
8.3.9 Thermische Desinfektion
...
Address
...
Datapoint Typ
...
R/W
...
Range
...
Unit
...
Name
...
Min.
...
Max.
...
Zeitfunktion
...
Start Stunde
...
1065u
...
uint16
...
R/W
...
0
...
23
...
hour
...
Start Minute
...
1066u
...
uint16
...
R/W
...
0
...
59
...
min
...
Sonntag
...
1073u
...
uint16
...
R/W
...
0
...
1
...
Montag
...
1067u
...
uint16
...
R/W
...
0
...
1
...
Dienstag
...
1068u
...
uint16
...
R/W
...
0
...
1
...
Mittwoch
...
1069u
...
uint16
...
R/W
...
0
...
1
...
Donnerstag
...
1070u
...
uint16
...
R/W
...
0
...
1
...
Freitag
...
1071u
...
uint16
...
R/W
...
0
...
1
...
Samstag
...
1072u
...
uint16
...
R/W
...
0
...
1
...
0: Ja
1: Nein
...
Temperatur
...
1074u
...
uint16
...
R/W
...
60
...
85
...
°C
8.3.10 Warmwasser Zirkulationspumpe
...
Address
...
Datapoint Typ
...
R/W
...
Range
...
Unit
...
Name
...
Min
...
Max
...
Zeitfunktion
...
Start Stunde 1
...
1081u
...
uint16
...
R/W
...
0
...
23
...
hour
...
Start Minute 1
...
1082u
...
uint16
...
R/W
...
0
...
59
...
min
...
Ende Stunde 1
...
1083u
...
uint16
...
R/W
...
0
...
23
...
hour
...
Ende Minute 1
...
1084u
...
uint16
...
R/W
...
0
...
59
...
min
...
Start Stunde 2
...
1085u
...
uint16
...
R/W
...
0
...
23
...
hour
...
Start Minute 2
...
1086u
...
uint16
...
R/W
...
0
...
59
...
min
...
Ende Stunde 2
...
1087u
...
uint16
...
R/W
...
0
...
23
...
hour
...
Ende Minute 2
...
1088u
...
uint16
...
R/W
...
0
...
59
...
min
...
Sonntag
...
1096u
...
uint16
...
R/W
...
0
...
3
...
Montag
...
1089u
...
uint16
...
R/W
...
0
...
3
...
Dienstag
...
1090u
...
uint16
...
R/W
...
0
...
3
...
Mittwoch
...
1091u
...
uint16
...
R/W
...
0
...
3
...
Donnerstag
...
1092u
...
uint16
...
R/W
...
0
...
3
...
Freitag
...
1093u
...
uint16
...
R/W
...
0
...
3
...
Samstag
...
1095u
...
uint16
...
R/W
...
0
...
3
...
0: Ja
1: Nein
2: Zeit 1
3: Zeit 2
8.4 Displayanzeigen
...
Address
...
Datapoint Typ
...
R/W
...
Range
...
Name
...
Min
...
Max
...
...
530u
...
uint16
...
R
...
0
...
30
...
...
533u
...
uint16
...
R
...
1
...
42
...
...
531u
...
uuint16
...
R
...
1
...
31
...
...
532u
...
uint16
...
R
...
1
...
27
8.4.1 Statusmeldungen
...
Value
...
Description
...
0
...
Aus
...
1
...
Aus
...
2
...
Heizen
...
3
...
Schwimmbad
...
4
...
Warmwasser
...
5
...
Kühlen
...
10
...
Abtauen
...
11
...
Durchflussüberwachung
...
24
...
Verzögerung Betriebsmodusumschaltung
...
30
...
Sperren (siehe Kapitel Sperren)
8.4.2 Sperren
...
Value
...
Description
...
2
...
Volumenstrom
...
5
...
Funktionskontrolle
...
6
...
Einsatzgrenze HT
...
7
...
Systemkontrolle
...
8
...
Verzögerung Umschaltung Kühlen
...
9
...
Pumpenvorlauf
...
10
...
Mindeststandzeit
...
11
...
Netzbelastung
...
12
...
Schaltspielsperre
...
13
...
Warmwasser Nacherwärmung
...
14
...
Regenerativ
...
15
...
EVU-Sperre
...
16
...
Sanftanlasser
...
17
...
Durchfluss
...
18
...
Einsatzgrenze Wärmepumpe
...
19
...
Hochdruck
...
20
...
Niederdruck
...
21
...
Einsatzgrenze Wärmequelle
...
23
...
System Grenze
...
24
...
Last Primärkreis
...
25
...
Sperre Extern
...
31
...
Aufwärmen
...
33
...
EvD Initialisierung
...
34
...
2.Wärmeerzeuger freigegeben
...
35
...
Störung (siehe Kapitel Störmeldungen)
8.4.3 Störmeldungen
...
Value
...
Description
...
0
...
kein Fehler
...
1
...
Fehler N17.1
...
2
...
Fehler N17.2
...
3
...
Fehler N17.3
...
4
...
Fehler N17.4
...
6
...
Elektronisches Ex.Ventil
...
10
...
WPIO
...
12
...
Inverter
...
13
...
WQIF
...
15
...
Sensorik (siehe Kapitel Sensorik)
...
16
...
Niederdruck Sole
...
19
...
!Primärkreis
...
20
...
!Abtauen
...
21
...
!Niederdruck Sole
...
22
...
!Warmwasser
...
23
...
!Last Verdichter
...
24
...
!Codierung
...
25
...
!Niederdruck
...
26
...
!Frostschutz
...
28
...
!Hochdruck
...
29
...
!Temperatur Differenz
...
30
...
!Heisgasthermostat
...
31
...
!Durchfluss
Min | Max | ||||
---|---|---|---|---|---|
Statusmeldungen | 530u | uint16 | R | 0 | 30 |
Sperrmeldungen | 533u | uint16 | R | 1 | 42 |
Störmeldungen | 531u | uint16 | R | 1 | 31 |
Sensorfehler | 532u | uint16 | R | 1 | 27 |
Cp content card macro | ||
---|---|---|
|